Roar Prime
Recover faster. Feel sharper. Roar Prime drops and maintains your plunge water between 3–26 °C, with dependable cooling power and simple, plug-and-go setup.
Key benefits
-
Serious cooling power: 2,200 W cooling capacity; chills 400 L to 10 °C in ~4 hours
-
Wide temp range: set anywhere from 3–26 °C for beginners to pros
-
Steady, consistent sessions: 900 L/h circulation to prevent hot spots
-
Compact footprint: only 35 × 30 × 35 cm, 25.6 kg
-
Simple power: 220–240 V AC (50 Hz), 3-pin plug
-
R410A refrigerant with efficient, reliable 750 W compressor
Who it’s for
Home plunge owners, coaches, gyms, studios, and recovery clinics that want true cold without the daily ice run. If your tub is up to 500 L, Roar Prime delivers fast pull-down and rock-solid temperature holding for consistent protocols.
What’s included
- 1x Roar Plunge™ Chiller
- 1x Filter System
- 1x Hose Set with Insulation
- 1x Water Pump
- 1x Roar Plunge™ Bathtub
- 1x Insulated Lid
- 1x Lid Cover
- 1x Inflatable Pillow
- 1x Storage Bag
- 1x Hand Pump
- 2x Vinyl Repair Patch
Specs (at a glance)
| Category | Detail |
|---|---|
| Cooling Capacity | 2200 W |
| Operating Power | 1.0 HP |
| Input Power | 800 W |
| Compressor Power | 750 W |
| Water Temp Range | 3–26 °C |
| Cooling Time | ~4 h to 10 °C (from ambient) in 400 L |
| Flow Rate | 900 L/h (15 L/min) |
| Power Supply | 220–240 V AC, 50 Hz |
| Plug | 3-pin |
| Refrigerant | R410A |
| Dimensions (L × W × H) | 35 × 30 × 35 cm |
| Weight | 25.6 kg |
| System Capacity (Tub Volume) | 400 L |
| Noise @ 1 m | 30 dB (Eco/Standard) |
Performance
-
Fast pull-down: Typical 400 L tub from room temperature to 10 °C in ~4 hours.
-
Stable temps for repeatability: 900 L/h recirculation helps maintain uniform water temperature across the tub.
-
Programmable range: 3–26 °C supports gradual adaptation and advanced protocols.
Installation & Placement
-
Position Roar Prime on a flat, ventilated surface.
-
Connect inlet/outlet hoses (hand-tighten; no tools needed).
-
Fill your tub to the recommended level and prime the lines.
-
Power on (220–240 V AC, 50 Hz, 3-pin).
-
Set your target temperature and let the system pull down.
Drainage: ensure water can be routed to a floor drain or outdoor area when you empty the tub.
Floor load note: A 400 L tub weighs ~400 kg when filled (plus tub & person).
Maintenance
-
Filter care: Inspect weekly; clean/replace per use conditions (every 2–4 weeks).
-
Water management: Skim debris; change water based on use and sanitation method.
-
Sanitation compatibility: Works with common cold-plunge sanitation routines.
-
Seasonal check: Inspect hoses, fittings, and electrical annually.
Safety & Compliance
-
Electrical: Use a properly grounded outlet; GFCI/RCD protection strongly recommended. Do not use extension leads.
-
Use guidelines: Start with shorter exposures; do not plunge alone.
-
Health notice: Cold exposure may not be appropriate for everyone (cardiovascular conditions, pregnancy, etc.). Consult a healthcare professional.
- Refrigerant: R410A (service by qualified technicians only).
Shipping & Delivery
-
Lead time: 3-5 working days.
-
Method: Freight delivery (curbside as standard); white-glove available in select areas.
- On arrival: Inspect packaging; photograph any damage before signing and contact support.
Warranty & Returns
-
Warranty: 2-year chiller, 1-year hoses/fittings
-
What’s covered: Defects in materials/workmanship under normal use.
-
Returns: 30-day return window; restocking fee may apply; return freight by customer unless DOA.
Full terms: Return Policy
FAQs
- Will Roar Prime work with my tub?
Roar Prime is a complete system (chiller + insulated tub) engineered to work together. Capacity is 500 L, so you don’t need to supply a separate tub. If you need a different size or a chiller-only setup, check our other models or contact us for a recommendation. - How long to get really cold?
From room temp, expect ~4 hours to reach 10 °C in a 400 L tub. Smaller volumes chill faster. - What power do I need?
220–240 V AC, 50 Hz via a 3-pin outlet. Use a properly grounded, protected circuit. Avoid extension leads. - Is it outdoor-safe?
Place under cover, on a level surface with ventilation. - What about maintenance?
Rinse/replace filters regularly, skim debris, and change water per your sanitation routine. - How loud is it?
Noise level is 30 dB. - Which chemicals are compatible?
Use cold-plunge-safe products only. Avoid anything that may damage seals/hoses. - Does it heat as well?
Roar Prime is a cooling system (3–26 °C).
Got questions? Check our FAQ or ping us on WhatsApp—we reply within minutes.












Lim Wei Ming –
Love the physical temperature dial—no apps, no lag, just ice-cold water on demand.
Nurul Aisyah Binti Mohamad –
Large size fits my 6-ft husband comfortably—build feels solid.
Wong Chee Keong –
Standard size fits perfectly in my home gym, wish I went for the Large though since I’m quite tall, but still very comfortable.
Ahmad Haziq –
Absolutely fantastic! Reaches 3°C super fast even during hot days, and the 450L Large size fits me perfectly.
Chong Mei Ling –
Solid! LED display is quite nice, manual controls take a bit getting used to.
Siti Aminah –
Quiet chiller and ozone filter keep the water clear; only topped up once in four weeks.